SMOKE LIFT

GLASS SKYLIGHT

F100

SMOKE LIFT

GLASS SKYLIGHT

F100

SMOKE LIFT

GLASS SKYLIGHT

F100

LAMILUX Smoke Lift Glass Skylight F100

The PVC framed glass skylight for daylight and EN 12101-2 certified smoke and heat exhaust ventilation


Smoke vent in open position

The Smoke Lift Glass Skylight F100 combines all the advantages of the F100 Glass Skylight with the safety features of an EN 12101-2 certified electrical smoke and heat exhaust ventilator. It is suitable for flat roof residential and administrative or school building projects and achieves high levels of wind and rain resistance, excellent air tightness and thermal insulation values. With multi stage ventilation, it can also provide comfort for everyday use in addition to safety in the event of a fire.

Features and benefits

Quality

• CE marked quality according to EN 14351 and EN12101-2 certified

• Factory production approved to ISO 9001:2015, which means the quality products are manufactured to a consistently high standard

• Fully factory assembled product - producing a superior quality product that reduces on-site installation time

• Enhanced isothermal characteristics in the overall construction – resulting in achieving maximum energy efficiency and thermal insulation

Design

• Thermally broken white PVC free of thermal bridges saving heating costs

• Multi layered double sealing system as standard - which reduces the risk of condensation, mould growth and air leakage

• GRP heat-insulated upstand with seamless silk-white interior finish removes the need of internal plastering

• Delivered pre-assembled to GRP upstand - removing the need for creating timber curved upstands

Comfort

• High daylight incidence with a light Transmittance value of 80% (reference double glazed)

• Effective acoustics and soundproofing with a sound insulation value of Rw,p 38dB (reference double glazed rooflight)

• Excellent U-values supporting whole product efficiency - Utotal 1.3W/m²K and Ug-Value 1.1W/m²K (reference F100G-S14)

• Pleasant indoor climate thanks to optional natural ventilation

Use

• Suited for application within residential, commercial and public buildings

• Affordable AOV for flat roofs, and roofs up to a 10° pitch, without compromising on performance levels 

• Opens to 165° in under 60 seconds to channel smoke, heat and toxic gases quickly out of the building ensuring safety in the event of a fire

• Versatile product for daylight and smoke and heat ventilation in case of fire

Standard offering


LAMILUX have selected the most popular specifications to form a standard range in the Smoke Lift Glass Skylight F100 range, with faster delivery times. Simply relay the below product codes when discussing your rooflight requirements with the LAMILUX team. 

Close up of glazing section

Glazing: double glazed

• Fragility TN92 class 2
• Ug-value: c. 1.1 W/(m²K)
• Sound insulation: c. 38 dB
• Light transmittance: c. 80 %
• Energy transmission: c. 0.57

square upstand image

Upstand: 300mm high steep

• GRP heat-insulated upstand
• PVC cap flashing included
• Seamless silk-white interior
• Heat-resistant for hot melt processes
• Pre-assembled for quick and easy installation

Isothermal line diagram of SHEV

Framework: white PVC

• Thermally broken PVC frame
• RAL 9016 - White
• 10° isotherm line for consistent heat insulation

Internal view showcasing SHEV fitting

SHEV Fitting

• Opening angle approx. 165°
• Mill finish galvanised
• 24v solo motor 7.5A

F100 Glass Smoke and Heat Exhaust Ventilation (SHEV)

Standard product codes

Product code

Structural roof opening size

Aerodynamic free area (Aa)

F100G-S14-S

1200 x 1200mm

1.02m²

Specification and Drawing Downloads

SPECIFICATION

NBS Source

NBS logo

F100G-S14-S

Aa 1.02m² - PDF

PDF logo

F100G-S14-S

Aa 1.02m² - DWG

Controls


LAMILUX offer a range of controls to provide the complete solution to Smoke and Ventilation requirements. The LAMILUX standard controls package (order code LUX-01) consists of a Control Panel, Manual Control Point and Smoke Detector

Click here to view the standard controls package

LUX-01 - Control kit

If standard is not what you're looking for

Contact our sales team for more options on the Smoke Lift Glass Skylight F100 range


Other sizes, glazing options, upstand heights and accesories are also available. Call 01284 749051 or email the team at sales(at)lamilux.co.uk now to discuss your non-standard requirements. 

youtube-placeholder

Design details

Smoke Lift Glass Skylight F100 technical design characteristics


Energy efficiency

The Smoke Lift Glass Skylight F100 is the PVC framed square or rectangle shaped glass AOV skylight with maximum energy efficiency and thermal insulation. With high levels of wind and rain resistance, alongside enhanced isothermal characteristics in the overall construction – the unrivalled performance of this range results in no condensation alongside excellent air tightness values. The thermally broken “isothermally balanced” PVC frames feature optimally aligned 10° isotherm line. This means that the thermally broken 10° isothermal line remains within the structure (see diagram) for consistent heat insulation without any weak spots, reducing condensation, mould and bacteria. The TIP (Total Insulated Product) is certified in accordance with EN ISO 14021.

Performance

•    CE marked quality according to EN 1873
•    EN 12101-2 certified electrical smoke and heat exhaust ventilator
•    Life Cycle Assessment (LCA) to EN 15804
•    Airtight to Class 4, EN 12207
•    Water tightness to Class 4 according to BS EN 12208
•    Wind Load to Class C4, EN 12210
•    CWCT Class 2 Non-fragile

Quality control of component manufacture: 

•    Energy management system to EN ISO 50001:2011
•    Quality management system to EN ISO 9001:2015  

Design detail cross section

Design detail

1 - Glazing: Toughened outer and laminated safety inner

2 - Smooth crossover between glazing and frame profile, ensuring rainwater can run-off easily without any dirty edges

3 - Thermally broken White PVC (RAL 9016) frame

4 - Multi layered airtight double sealing system

5 - Thermally insulated GRP upstand with seamless silk-white interior finish (RAL 9016)

Smoke Lift Glass Skylight F100 Downloads

LAMILUX SHEV SYSTEMS

Brochure

PDF logo

ROOFS OF LIGHT

General brochure

PDF logo

GLASS SKYLIGHTS

Brochure

PDF logo

ECO BUSINESS CENTRE

Case study

PDF logo

UPSTANDS

The perfect connection

PDF logo

DATA SHEET

Technical detail

PDF logo

People also viewed:

Dome Smoke vent rooflight

Smoke Lift Rooflight F100

Polycarbonate SHEV for daylight

Single flap closed SHEV unit on roof

roda Venturi

EN 12101-2 complient natural smoke and heat extraction system

Aluminium framed smoke vent

Smoke Lift FE

Aluminium framed smoke vent

PVC framed glass rooflight

Glass Skylight F100

Rooflight for daylight and natural ventilation